R-717 (Ammonia) Refrigerant Line Capacities
R-717 (Ammonia) Refrigerant Line Capacities
Tons for 100 ft.
R-717 (Ammonia) Tons for 100 Ft. |
Δp |
|||||||
---|---|---|---|---|---|---|---|---|
IPS |
Δp |
-40 |
-20 |
0 |
20 |
40 |
3 |
2 |
Sch |
0.31 |
0.49 |
0.73 |
1.06 |
1.46 |
|||
3/4 |
80 |
- |
- |
- |
2.6 |
3.8 |
- |
- |
1 |
- |
- |
2.1 |
3.4 |
5.2 |
7.6 |
13.9 |
106 |
1-1/4 |
40 |
3.2 |
5.6 |
8.9 |
13.6 |
19.9 |
36.5 |
229a |
1-1/2 |
- |
4.9 |
8.4 |
13.4 |
20.5 |
29.9 |
54.8 |
349a |
2 |
- |
9.5 |
16.2 |
26.0 |
39.6 |
57.8 |
106 |
811 |
2-1/2 |
- |
15.3 |
25.9 |
41.5 |
63.2 |
92.1 |
168 |
1293 |
3 |
- |
27.1 |
46.1 |
73.5 |
112 |
163 |
298 |
2288 |
4 |
- |
55.7 |
94.2 |
150 |
229 |
333 |
600 |
4662 |
5 |
- |
101 |
170 |
271 |
412 |
601 |
1095 |
- |
6 |
- |
164 |
276 |
439 |
668 |
972 |
1771 |
- |
- Adapted from ASHRAE HVAC Refrigeration Handbook